CONTEC Portable Ambulatory Blood Pressure Monitor AMPM SPO2 NIBP/+Cuff+Probe NEW PC Software

From R3892.58
  • Ships From:

  • Color:

Categories:

Buy With Confidence

100% Safe Payment


;

  • Description

    CONTEC Portable Blood Pressure NIBP/Spo2 +Cuff+Probe NEW PM50

    Description
    The Machine is a multifunctional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health care.
    Major Features
    1.Compact and portable, easy to use
    2.With Integrative SpO2 Probe
    3.Double working modes,monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set
    4.NIBP and SpO2 can be monitored for a long time
    5.NIBP and SpO2 data record for large capacity
    6.With friendly user interface, the user can see list menu and review measure results
    7.The device can display low power information, alarm information, error information and time information richly
    8.Parameter alarm function is optional
    9.Patient information can be flexibly set
    10.Case management function.PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions
    Main performance
    1.NIBP
    Measure Method: Oscillometry
    Measure Mode: The upper arm measure
    Measure range:
    ADULT:       SYS: 40mmHg~270mmHg
    MAP:20mmHg~235mmHg
    DIA: 10mmHg~215mmHg
    PEDIATRIC:     SYS: 40mmHg~200mmHg
    MAP: 20mmHg~165mmHg
    DIA: 10mmHg~150mmHg
    NEONATAL:     SYS: 40mmHg~135mmHg
    MAP: 20mmHg~110mmHg
    DIA: 10mmHg~100mmHg
    Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes
    Resolution: 1mmHg
    Accuracy:  ±3mmHg
    Increasing pressure mode: force pump increases pressure automatically
    Reducing pressure mode: self-motion ladder reducing pressure mode
    Alarm parameter: SYS / MAP / DIA
    2.SPO2
    Measure range: 0%~100% (Resolution:1%)
    Accuracy: 70-100%, ±2%, below 70% unspecified
    Error in Weak Filling Condition:
    SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
    Resistance to surrounding light:
    The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
    3.Pulse Rate
    Measuring range:0bpm~250bpm
    Resolution:1bpm
    Accuracy: ±2 bpm or ±2% (select larger)
    4.Display: 2.4″ TFT colour LCD
    5.Power: DC 3V(Two “AA”,1.5V Alkali Battery)
    6.Product safety type:Type BF applied part (Internally powered,defibrillation-proof)
    Accessories
    Cuff for adult.
    Integrative SpO2 Probe
    USB data line
    Pack
    User manual
    Physical Identity
    Dimension: 128mm*69mm*36 mm (No including Packing)
    Weight: <350g (Including Batteries)
    Software function
    1.Up to 1000 patient cases can be edited and supervised.
    2.The time segment of dealing with the patient’s NIBP data is 48 hours.
    3.Connect the device by USB interface.
    4.Can upload patient information data collection project and download collection data.
    5.Can display scoop-shape trend graph,filling-type trend graph, histogram, pie chart, correlation line graph.
    6.Can edit every piece of data, and add annotation to it.
    7.Can edit basic information,doctor’s advice information, NIBP and SpO2 status instruction, current medicine-taken information, etc. Support print preview, print the report.